Particle Physics and Frontiers of Physics
133 Accelerators Create Matter from Energy
Learning Objectives
- Explain how particle accelerators use electric and magnetic fields to accelerate charged particles.
- Describe the operating principles of a cyclotron and a synchrotron.
- Calculate the accelerating voltage required between accelerator gaps.
- Explain why colliding-beam accelerators are more effective than fixed-target accelerators for producing new particles.
- Describe several scientific and medical applications of modern particle accelerators.
Particle accelerators are among the largest and most technologically advanced scientific instruments ever constructed. They allow scientists to investigate the structure of matter by giving charged particles very large kinetic energies and directing them toward targets or into collisions with other particles.
Accelerators have played a central role in the discovery of atomic nuclei, quarks, neutrinos, antimatter, the weak-interaction bosons, and the Higgs boson. They are also used outside particle physics in medicine, biology, chemistry, materials science, archaeology, and industry.
The operating principle of a particle accelerator follows directly from the behavior of charged particles in electric and magnetic fields. An electric field can increase a charged particle’s kinetic energy. A magnetic field can bend the particle’s path and keep it moving through the accelerator.
Higher particle energies serve two important purposes. First, the de Broglie wavelength of a particle decreases as its momentum increases. High-energy particles can therefore probe structures at very small length scales. Second, collision energy can be converted into the rest energy of newly created particles.
Einstein’s mass-energy relationship can be written as
If an amount of collision energy [latex]\Delta E[/latex] is converted into rest energy, the corresponding mass is
This means that sufficiently energetic collisions can create particles that were not present before the collision.
The First Particle Accelerators
The earliest particle accelerators used large electric potential differences to accelerate charged particles. When a particle of charge [latex]q[/latex] moves through a potential difference [latex]V[/latex], its electric potential energy changes by
If this energy is converted into kinetic energy, the particle gains an amount
A particle carrying one elementary charge gains 1 electron volt of energy when it moves through a potential difference of 1 volt. Therefore, a proton accelerated through a potential difference of 1 million volts gains 1 MeV of kinetic energy.
One early accelerator design was the Van de Graaff generator. A moving insulating belt transports electric charge to a large conducting sphere. Because the charge spreads across the sphere’s outer surface, the sphere can reach an extremely high electric potential.
Charged particles can then be accelerated through the resulting potential difference. Van de Graaff accelerators were widely used in early nuclear-physics experiments and remain useful for research, education, and calibration.

A major limitation of an electrostatic accelerator is that the particle passes through the accelerating voltage only once. Producing much higher energies would require impractically large potential differences.
A cyclotron avoids this limitation by allowing a charged particle to cross the same accelerating gap repeatedly.
The Cyclotron
A cyclotron consists of two hollow, D-shaped conducting electrodes called dees. The dees are placed between the poles of a magnet so that a magnetic field is directed perpendicular to the plane of the particle’s motion.
Inside either dee, the electric field is approximately zero. The magnetic force bends the charged particle into a semicircular path. When the particle reaches the gap between the dees, an alternating voltage creates an electric field that accelerates the particle.
The voltage reverses direction while the particle travels through a dee. When the particle reaches the gap again, the electric field points in the correct direction to accelerate it a second time.
The magnetic force on a particle of charge [latex]q[/latex] moving perpendicular to a magnetic field [latex]B[/latex] is
This magnetic force supplies the centripetal force:
Solving for the radius gives
As the particle gains speed, the radius of its path increases. The particle therefore follows an outward spiral until it reaches the edge of the cyclotron and is extracted as a beam.

For nonrelativistic particles, the time required to complete one semicircle is independent of the particle’s speed. This allows the alternating voltage to remain synchronized with the particle’s motion.
The cyclotron frequency is
This simple relationship is one of the major advantages of the cyclotron. However, when a particle approaches the speed of light, relativistic effects become important. The fixed cyclotron frequency no longer remains properly synchronized with the particle’s motion. More advanced accelerator designs are needed to reach higher energies.
Modern Accelerators and Colliding Beams
As particle physicists sought to probe smaller structures and discover heavier particles, accelerators became progressively larger and more powerful. Increasing a particle’s energy decreases its associated de Broglie wavelength, allowing scientists to investigate matter at increasingly smaller length scales. Higher collision energies also make it possible to create more massive particles through Einstein’s mass-energy equivalence.
Early accelerator experiments directed a high-energy beam onto a stationary target. Although this approach remains valuable for many applications, part of the beam energy is converted into the motion of the collision products rather than into the creation of new particles. As a result, only a fraction of the available energy can produce new matter.
A much more efficient approach is to collide two particle beams traveling in opposite directions. In these colliding-beam accelerators, the total momentum before the collision is nearly zero, allowing a much larger fraction of the available energy to be converted directly into the masses of newly created particles. This design has become the standard for the world’s highest-energy particle physics experiments.
Many colliders accelerate particles and their corresponding antiparticles, such as electrons and positrons or protons and antiprotons. Because these particles have opposite electric charges, they can often circulate through the same magnetic system in opposite directions before being brought into head-on collisions inside large particle detectors.
Modern proton colliders, including the Large Hadron Collider, instead accelerate two counter-rotating proton beams in separate beam pipes that intersect at several collision points.
Synchrotrons
A synchrotron is a circular accelerator in which particles travel around a path of nearly constant radius. Unlike a cyclotron, a synchrotron changes the magnetic field as the particles gain energy.
Radio-frequency accelerating cavities provide electric fields that increase the particles’ energy each time they pass through. At the same time, electromagnets guide and focus the beam.
Because the particle momentum increases during acceleration, the magnetic field must also increase to maintain the same orbit. The magnetic field and accelerating frequency are synchronized with the motion of the particles.

Healthcare Connection: Synchrotrons Beyond Particle Physics
Many synchrotrons are built not to discover new particles but to produce extremely bright X-ray beams for research. Synchrotron radiation is widely used to determine the three-dimensional structures of proteins, viruses, DNA, and other biological molecules through X-ray crystallography and related techniques.
These studies have contributed to drug development, vaccine design, and our understanding of numerous diseases.
Particle Colliders and Detectors

The detectors used at modern particle accelerators are as remarkable as the accelerators themselves. They surround the collision point with multiple layers of specialized instruments that identify particles, measure their energies and momenta, and reconstruct the interactions that occurred during the collision.
Because many newly created particles exist for only tiny fractions of a second, they are detected indirectly through the particles into which they decay.
For nearly three decades, the Tevatron at Fermilab in the United States was the world’s highest-energy particle collider. It accelerated protons and antiprotons to energies of about 1 TeV each and played a central role in discoveries such as the top quark.
Today, the world’s most powerful particle accelerator is the Large Hadron Collider (LHC) at CERN near Geneva, Switzerland. The LHC accelerates two counter-rotating proton beams around a 27-km circular tunnel using thousands of superconducting magnets.
It currently operates at a center-of-mass collision energy of up to 13.6 TeV, enabling studies of the Higgs boson, searches for new particles, and precise tests of the Standard Model of particle physics.
Plans for even larger accelerators continue to be explored around the world. Proposed facilities would extend collision energies beyond those currently achievable, allowing physicists to investigate unanswered questions about dark matter, neutrino properties, and physics beyond the Standard Model.
Linear Accelerators
Not all particle accelerators are circular. A linear accelerator, or LINAC, accelerates particles along a straight path using a series of radio-frequency accelerating cavities.
Because the particles do not travel in circular orbits, linear accelerators avoid the energy losses caused by synchrotron radiation. This advantage is especially important for lightweight particles such as electrons.
The Stanford Linear Accelerator Center in California pioneered high-energy electron acceleration and provided the first convincing experimental evidence that protons and neutrons contain smaller constituents called quarks. Similar accelerator technology is now used in many scientific laboratories around the world.
Healthcare Connection: Medical Linear Accelerators
Linear accelerators are among the most important particle accelerators used in medicine. Medical LINACs generate high-energy electron or X-ray beams that are used to treat cancer through external beam radiation therapy.
Modern systems can shape and modulate the radiation beam to deliver high doses to tumors while minimizing damage to surrounding healthy tissue.

Worked Example: Calculating the Accelerating Voltage Between Cavities
A linear accelerator is designed to produce a beam of 800-MeV protons using 2000 accelerating cavities. What average voltage must be applied across each accelerating gap to achieve the desired beam energy?
Strategy
Each time a proton crosses an accelerating gap, it gains electrical potential energy given by
where [latex]q[/latex] is the proton’s charge and [latex]V[/latex] is the potential difference across the gap.
Because one electron volt is the energy gained by a particle carrying one elementary charge moving through a potential difference of 1 V, a proton gains 1 eV of energy for every volt of accelerating potential.
The total accelerating voltage required is therefore 800 MV. Dividing this total evenly among the 2000 accelerating gaps gives the average voltage across each gap.
Solution
Discussion
A voltage of approximately 400 kV across each accelerating gap is readily achievable in a high-vacuum accelerator.
Rather than greatly increasing the voltage across individual gaps, modern accelerators achieve much higher particle energies by using thousands of accelerating cavities or by allowing particles to pass repeatedly through the same accelerating structures, as in synchrotrons.
Section Summary
- Particle accelerators use electric fields to increase the kinetic energy of charged particles and magnetic fields to guide their motion.
- Van de Graaff generators, cyclotrons, synchrotrons, and linear accelerators represent important stages in the development of accelerator technology.
- A cyclotron uses a constant magnetic field and an alternating electric field to accelerate particles along an outward spiral path.
- Synchrotrons keep particles in nearly circular orbits by synchronizing accelerating electric fields with increasing magnetic fields.
- Colliding-beam accelerators make much more energy available for creating new particles than fixed-target experiments because less energy is carried away as the motion of the collision products.
- Linear accelerators accelerate charged particles along straight paths using radio-frequency cavities.
- Modern accelerator facilities are used not only in particle physics but also in medicine, biology, materials science, and many other fields of research.
Conceptual Questions
- The total energy stored in the beam of a particle accelerator is much greater than the energy of an individual beam particle. Why can't all of this energy be used to create a single extremely massive particle?
- Synchrotron radiation causes accelerated charged particles to lose energy. Why is this effect much more significant for electron accelerators than for proton accelerators?
- What two major engineering limitations make it difficult to build compact particle accelerators that reach extremely high energies?
- What are the advantages and disadvantages of colliding-beam accelerators compared with fixed-target accelerators?
Problems & Exercises
- A proton traveling in the 2.00-km-diameter Fermilab synchrotron moves at nearly the speed of light because its kinetic energy is much larger than its rest-mass energy.
- How long does it take the proton to complete one revolution?
- How many times per second does it pass a fixed point in the accelerator?
- Suppose a [latex]W^-[/latex] boson created in a particle detector exists for [latex]5.00\times10^{-25}\,\text{s}[/latex]. What distance does it travel if it moves at [latex]0.900c[/latex]? Since this distance is extremely small, the particle must be identified through its decay products rather than by observing a visible track.
- What length of track does a [latex]\pi^+[/latex] meson traveling at [latex]0.100c[/latex] produce if it lives for [latex]2.60\times10^{-8}\,\text{s}[/latex] before decaying?
- The 3.20-km-long Stanford Linear Accelerator (SLAC) produces a beam of 50.0-GeV electrons. If the accelerator contains 15,000 accelerating cavities, what average voltage must be applied across each accelerating gap?
- Because of synchrotron-radiation losses in the Large Hadron Collider (LHC), only 5.00 MeV of energy is added to each proton during every revolution. If protons enter the accelerator with an energy of 8.00 GeV, how many revolutions are required to reach a beam energy of 7.00 TeV?
- A proton and an antiproton collide head-on, each with a kinetic energy of 7.00 TeV. What total collision energy is available when both the kinetic energy and the particles' rest-mass energy are considered?
- When an electron and a positron collide in a high-energy linear accelerator, each has a kinetic energy of 50.0 GeV. What total collision energy is available when the particles annihilate?
Glossary
- colliding beams
- Two beams of particles traveling in opposite directions that collide head-on, allowing much more of the beam energy to be converted into the creation of new particles.
- cyclotron
- A circular particle accelerator that uses a constant magnetic field and an alternating electric field to accelerate charged particles along an outward spiral path.
- linear accelerator (LINAC)
- A particle accelerator that accelerates charged particles along a straight path using a series of radio-frequency accelerating cavities.
- synchrotron
- A circular accelerator in which both the magnetic field and the radio-frequency accelerating field are synchronized with the increasing energy of the particles so they remain on a nearly constant-radius orbit.
- synchrotron radiation
- Electromagnetic radiation emitted by charged particles when they are accelerated perpendicular to their direction of motion, such as when they travel around curved paths in a magnetic field.
- Van de Graaff generator
- An electrostatic accelerator that uses a moving belt to transport electric charge to a large conducting sphere, producing very high voltages for accelerating charged particles.
Two beams of particles traveling in opposite directions that collide head-on, allowing much more of the beam energy to be converted into the creation of new particles.
A circular particle accelerator that uses a constant magnetic field and an alternating electric field to accelerate charged particles along an outward spiral path.
A machine that accelerates electrons to produce high-energy x-rays or electron beams for external beam radiation therapy.
A circular accelerator in which both the magnetic field and the radio-frequency accelerating field are synchronized with the increasing energy of the particles so they remain on a nearly constant-radius orbit.
Electromagnetic radiation emitted by charged particles when they are accelerated perpendicular to their direction of motion, such as when they travel around curved paths in a magnetic field.
A machine that uses a moving insulating belt to accumulate a very large electric charge on a conducting sphere, producing extremely high voltages for demonstrations and scientific applications.